SAC Background Documents available through ATC
The SAC Background Document series has been developed to disseminate information related to the mission of the Steel Project that has not been reviewed as part of the formal report series. The Background Documents are not intended to be used for design or for any specific building project and do not necessarily represent official findings or recommendations of FEMA, the SAC Joint Venture and its organizations, or any other project participants.
To order these documents, please contact: Applied Technology Council, 555 Twin Dolphin Drive, Suite 550, Redwood City, California 94065, (650) 595-1542; FAX (650) 593-2320.
| SAC/BD-00/01 |
Parametric Tests on Unreinforced Connections, Volume I - Final Report, by K.-H. Lee, B. Stojadinovic, S. C. Goel, A. G. Margarian, J. Choi, A. Wongkaew, B. P. Reyher, and D.-Y, Lee |
| SAC/BD-00/01A |
Parametric Tests on Unreinforced Connections, Volume II - Appendices, by K.-H. Lee, B. Stojadinovic, S. C. Goel, A. G. Margarian, J. Choi, A. Wongkaew, B. P. Reyher, and D.-Y, Lee |
| SAC/BD-00/02 |
Parametric Tests on the Free Flange Connections, by J. Choi, B. Stojadinovic, and S. C. Goel |
| SAC/BD-00/03 |
Cyclic Tests on Simple Connections Including Effects of the Slab, by J. Liu and A. Astaneh-Asl |
| SAC/BD-00/04 |
Tests on Bolted Connections, Part I: Technical Report, by J. Swanson, R. Leon, and J. Smallridge |
| SAC/BD-00/04A |
Tests on Bolted Connections, Part II: Appendices, by J. Swanson, R. Leon, and J. Smallridge |
| SAC/BD-00/05 |
Bolted Flange Plate Connections, by S. P. Schneider and I. Teeraparbwong |
| SAC/BD-00/06 |
Round Robin Testing of Ultrasonic Testing Technicians, by R. E. Shaw, Jr. |
| SAC/BD-00/07 |
Dynamic Tension Tests of Simulated Welded Beam Flange Connections, by J. M. Ricles, C. Mao, E. J. Kaufmann, L.-W. Lu, and J. W. Fisher |
| SAC/BD-00/08 |
Design of Steel Moment Frame Model Buildings in Los Angeles, Seattle and Boston, by P. Clark |
| SAC/BD-00/09 |
Benchmarking of Analysis Programs for SMRF System Performance Studies, by A. Gupta and H. Krawinkler |
| SAC/BD-00/10 |
Loading Histories for Seismic Performance Testing of SMRF Components and Assemblies, by H. Krawinkler, A. Gupta, R. Medina, and N. Luco |
| SAC/BD-00/11 |
Development of Improved Post-Earthquake Inspection Procedures for Steel Moment Frame Buildings, by P. Clark |
| SAC/BD-00/12 |
Evaluation of the Effect of Welding Procedure on the Mechanical Properties of FCAW-S and SMAW Weld Metal Used in the Construction of Seismic Moment Frames, by M. Q. Johnson |
| SAC/BD-00/13 |
Preliminary Evaluation of Heat Affected Zone Toughness in Structural Shapes Used in the Construction of Seismic Moment Frames, by M. Q. Johnson and J. E. Ramirez |
| SAC/BD-00/14 |
Evaluation of Mechanical Properties in Full-Scale Connections and Recommended Minimum Weld Toughness for Moment Resisting Frames, by M. Q. Johnson, W. Mohr, and J. Barsom |
| SAC/BD-00/15 |
Simplified Design Models for Predicting the Seismic Performance of Steel Moment Frame Connections, by C. Roeder, R. G. Coons, and M. Hoit |
| SAC/BD-00/16 |
SAC Phase 2 Test Plan, by C. Roeder |
| SAC/BD-00/17 |
Behavior and Design of Radius-Cut, Reduced Beam Section Connections, by M. Engelhardt, G. Fry, S. Jones, M. Venti, and S. Holliday |
| SAC/BD-00/18 |
Test of a Free Flange Connection with a Composite Floor Slab, by M. Venti and M. Engelhardt |
| SAC/BD-00/19 |
Cyclic Testing of a Free Flange Moment Connection, by C. Gilton, B. Chi, and C.-M. Uang |
| SAC/BD-00/20 |
Improvement of Welded Connections Using Fracture Tough Overlays, by James Anderson, J. Duan, P. Maranian, and Y. Xiao |
| SAC/BD-00/21 |
Cyclic Testing of Bolted Moment End-Plate Connections, by T. Murray, E. Sumner, and T. Mays |
| SAC/BD-00/22 |
Cyclic Response of RBS Moment Connections: Loading Sequence and Lateral Bracing Effects, by Q. S. Yu, C. Gilton, and C. M. Uang |
| SAC/BD-00/23 |
Cyclic Response of RBS Moment Connections: Weak Axis Configuration and Deep Column Effects, by C. Gilton, B. Chi, and C. M. Uang |
| SAC/BD-00/24 |
Development and Evaluation of Improved Details for Ductile Welded Unreinforced Flange Connections, by J. M. Ricles, C. Mao, L.-W. Lu, and J. Fisher |
| SAC/BD-00/25 |
Performance Prediction and Evaluation of Steel Special Moment Frames for Seismic Loads, by K. Lee and D. A. Foutch |
| SAC/BD-00/26 |
Performance Prediction and Evaluation of Low Ductility Steel Moment Frames for Seismic Loads, by S. Yun and D. A. Foutch |
| SAC/BD-00/27 |
Steel Moment Resisting Connections Reinforced with Cover and Flange Plates, by T. Kim, A. S. Whittaker, V. V. Bertero, A. S. J. Gilani, and S. M. Takhirov |
| SAC/BD-00/28 |
Failure of a Column K-Area Fracture, by J. M. Barsom and J. V. Pellegrino |
| SAC/BD-00/29 |
Inspection Technology Workshop, by R. E. Shaw, Jr. |
| SAC/BD-00/30 |
Preliminary Assessment of the Impact of the Northridge Earthquake on Construction Costs of Steel Moment Frame Buildings, by Davis Langdon Adamson |
|